Dry Type Transformer 3-Phase 10KV/35KV 50/60Hz Power Distribution Projects May Shell Protective Enclosure

← Products

SCB

Dry Type Transformer 3-Phase 10KV/35KV 50/60Hz Power Distribution Projects May Shell Protective Enclosure

Product Description

The resin-insulated dry-type transformer is developed by our company through the introduction of advanced foreign technology, and the independent development of the SC9, SCB9 series, as well as the SC10, SCB10 series with thin insulation and filler. 

 

As the coil is encapsulated in epoxy resin, it is difficult to ignite, fireproof, explosion-proof, maintenance-free, pollution-free, and has a small size. It can be directly installed in the load center. Meanwhile, the scientific and reasonable design and casting process make the product have smaller partial discharge, low noise, strong heat dissipation capacity. It can operate for a long time under 140% rated load under forced air cooling conditions, and is equipped with an intelligent temperature control device, which has fault alarm, over-temperature alarm, over-temperature trip and black-box function. It is also connected to a computer through an RS485 serial interface, which can be centrally monitored and controlled.

 

Due to the above characteristics of our dry-type transformers, they are widely used in power transmission and transformation systems, such as hotels, airports, high-rise buildings, commercial centers, residential areas, and other important places, as well as harsh environments such as subways, smelters, ships, and offshore drilling platforms.

Model Meaning

The Model Designation of the SC(B)10 Series 11KV Three-Phase Resin-Insulated Dry-Type Transformer

Temperature Control System And Air Cooling System

The cross-flow top-blowing air-cooling fan is adopted, which has the characteristics of low noise, high wind pressure, and beautiful appearance, enhancing the overload capacity of the transformer. The temperature control adopts an intelligent temperature control device, which improves the safety and reliability of the transformer operation.

Technical Parameters

Rated Capacity
(KVA)

Voltage Group(KV)

HV/LV

Vector Group No-load Loss(KW) Load Loss
(KW)
No-Load
Current (%)
Impedance
Voltage
(%)
Weight
(kg)

Dimensioms
(mm)(L×W×H)

Mounting Dimensions
 (mm)(L×W×H)
External Dimensions With Enclosure(mm)
30 11
10
6
/
0.4
Dyn11
           Yyn0
0.19 0.71 2 4 270 590×500×640 400/400 1000×900×1050
50 0.27 1.0 2 360 620×550×670 400/400 1000×900×1050
80 0.37 1.38 1.5 510 680×580×710 400/450 1050×950×1100
100 0.4 1.57 1.5 570 720×600×720 400/450 1100×950×1150
125

0.47

1.85 1.3 600 860×650×850 550/550 1250×1000×1300
160 0.54 2.13 1.3 730 900×710×890 550/550 1300×1050×1350
200 0.62 2.53 1.1 850 940×750×980 550/660 1300×1100×1500
250 0.72 2.76 1.1 980 960×770×1030 660/660 1300×1100×1550
315 0.88 3.47 1 1130 1020×790×1060 660/660 1400×1150×1550
400 0.98 3.99 1 1330 1060×880×1100 660/820 1450×1200×1600
500 1.16 4.88 1 1480 1080×900×1160 660/820 1450×1200×1700
630 1.3 5.96 0.85 6 1580 1200×920×1150 820/820 1550×1200×1700
800 1.52 6.96 0.85 1910 1260×920×1260 820/820 1600×1200×1800
1000 1.77 8.13 0.85 2260 1320×940×1300 820/820 1700×1250×1800
1250 2.09 9.69 0.85 2660 1380×950×1380 820/820 1750×1250×1900
1600 2.45 11.73 0.85 3180 1460×1120×1490 1070/1070 1850×1400×2000
2000 3.05 14.45 0.7 3600 1490×1120×1620 1070/1070 1900×1450×2200
2500 3.6 17.17 0.7 4200 1520×1120×1760 1070/1070 1950×1500×2200
3150 5.04 22.5 0.6 5000 1600×1120×1860 1070/1070 2000×1550×2300
4000 5.96 29.8 0.6 6300 1680×1120×2150 1070/1070 2100×1600×2600